Success flash icon

Error flash icon

What is the scene dynamic range (SDR) of FLIR`s OEM modules?

The scene dynamic range (SDR) is shown below for FLIR`s OEM camera module products:

Camera     

High Gain Mode

Low Gain Mode     

Tau2 640, 324     

-25 °C to +135 °C 

-40 °C to +550 °C

Tau2 336

-25 °C to +100 °C

-40 °C to +550 °C

Quark2

-40 °C to +160 °C

Not Available

Muon

  50 °C above and below ambient temperature   

Lepton

0 °C to +120 °C

0 °C to +450 °C*

Boson

to 140 °C

to 500 °C

*Lepton Radiometric, only.

Note that Scene dynamic range is inversely proportional to the transmission loss introduced by a neutral density (ND) filter.

Introducing an ND filter with X transmission will increase the scene dynamic range by a factor of 1/X, assuming that the photon contribution coming from the filter itself is negligible.

For example, with a 0.65 ND filter, a Tau2 640 could potentially see up to 550 °C/0.65 = 850 °C in Low-Gain mode.